Prototype · internal review
How a PowerLift door works
Scroll slowly. The camera stops at each part of the door: the cylinders, the cylinder mount, the hinges, the frame and the power unit, then the door closes. Rendered offline; not shown on the live site yet.
How it's built
Inside a PowerLift hydraulic door
Loading film…
- The door. One welded steel leaf: A single-panel, fully welded steel door, custom built to 1/8" to fit the finished opening. Nothing bolts together.
- It opens. Open in 30-45 seconds: The leaf swings up and out on its top hinges and becomes a canopy. Typical close time is under 30 seconds.
- Cylinders. Two hydraulic cylinders: One on each side, fastened to the swinging leaf and to PowerLift's own door frame. Together they give at least 1,000 lbf of closing force.
- Cylinder mount. Upper cylinder mount: The barrel end pins to the PowerLift Upper Cylinder Mount on the stationary frame, so much of the cylinder load stays inside PowerLift's frame, not on the building.
- Hinges. Hinges through the header: Hinge blades are welded through the entire header tube and turn on PTFE-infused bronze bushings. No grease, ever (doors under 80' x 24').
- Frame. Its own steel frame: The leaf hangs on PowerLift's own structural frame (5" steel tube on Standard doors), not on the building header. The frame takes much of the door's weight straight to the ground.
- Power unit. Power unit and controls: Motor and pump in one 32.5" x 10.5" x 9.5" unit beside the door: 3 or 5 HP, 220/230 V, 30 A breaker. The switch is constant-hold, mounted 72" or higher.
- Closed. Hold Close to lock it: Keep holding Close for 3-5 seconds after the door shuts. The pressure locks it closed, tight against its own frame.
Exposed vs concealed cylinders
| Exposed cylinder | Concealed (HydAway) | |
|---|---|---|
| Cylinders | Two, inside the building between frame post and door leaf | Two, inside the frame jambs |
| Open / close | 30-45 s / under 30 s | Typically under 30 s |
| Clear-opening loss | Inside mount: about 5" of height and 6" of width. Outside mount: none | 4" or 6" of height and 8" or 12" of width |
| Power unit | 3 or 5 HP, 220/230 V (20' x 10' to 60' x 20'); up to 20 HP for larger doors | 1 HP, 110 V single phase, 20 A |
| Hose routing | From each cylinder down the frame to the wall-mounted unit | Through grommets into the header tube, JIC tees, then to the pump |
Sources
- PowerLift Technical Data Sheet, Rev H
- PowerLift Owner's Manual, 1-3 HP power units (rev 09.10.2025)
- PowerLift Standard Tube Jamb and Header Detail Drawings
- PowerLift Owner's Installation Checklist
- PowerLift Standard Door Power Unit Options sheet
- PowerLift 3-part spec 08 34 00 (ARCAT)
- powerliftdoors.com, PowerLift Advantages
- PowerLift Large Door Masterclass
- PowerLift Concealed Cylinder (HydAway) Technical Data Sheet, Rev B
- HydAway Hydraulic Wall Hose Routing Detail
- PowerLift Doors of Oregon, Tygh Valley project photos
The 3D model is drawn from these documents and the project photos. PowerLift doesn't publish cylinder bore, stroke, rod diameter or pressure, so the cylinder's proportions are illustrative and no such number is shown.
End of prototype. The scene is modeled on the Tygh Valley project photos. Part names and numbers come from the PowerLift documents on the Design Resources page (Technical Data Sheet, Owner's Manual, Owner's Installation Checklist, jamb and header drawings, power unit sheet, Large Door Masterclass), the PowerLift 3-part specification and powerliftdoors.com. Where PowerLift publishes no number, none is shown.